• Home skipcontent Sitemap screen-reader language
  • A-
  • A
  • A+
Search

Search.....

Click here to Search
  • Accident Intimation
  • NOC for Commercial
  • Downloads
  • Electric Charges
  • Authorized Login Panel
  • Download Softosignature
Vidyut Suraksha
  • Accident Intimation
  • NOC for Commercial
  • Downloads
  • Electric Charges
  • Authorized Login Panel
  • Download Softosignature
  • Home
  • Introduction
  • Organization
    • Headquarter Lucknow
    • Department Directory Details
    • Sanctioned Post
    • Right to Information Act 2005
      • Details of Public Information Officer
      • Details of Appel Author Officer
    • Sewa Niyamawali
      • Assistant Director Cadre
      • Electrical Safety Officer Cadre
      • Lipikiya Cadre
      • Steno Cadre
  • Administrative Work
  • Charges & Fee
    • Electric Charges
    • Inspection And Trial Fee
  • Suggestion For Public
  • Standard Drawing
    • Guidelines
    • Standard Drawing 1
    • Standard Drawing 2
    • Standard Drawing 3
    • Standard Drawing 4
  • Downloads
  • Check & Verify
    • Verify Noc Report
    • Verify Electricity Duty Exemption Report
    • Supervisor Verification
    • Wireman Verification
    • Contractor Verification
  • Online Application
    • Uttar Pradesh Lift and Escalator Registration Portal
    • NOC for Commercial
    • NOC for Industrial (Nivesh Mitra)
    • NOC Status
    • Apply for Periodical Inspection (Regulation 30)
    • Accident Intimation
    • Apply for exemption, adjustment, and refund of electricity duty
    • Apply for Supervisor certificate and wireman permit
    • Download Softosignature
  • Contact

Suggestions For Public

What Not To Do

  • Electricity does not look. Do not touch broken and hanging electric wire. There can be electricity in it and you can be victim of mischief.
  • Do not touch electric poles or stevair. There may be electricity in it or accidental power can come and you can get crashed.
  • Do not bury your animals near the pollen of electricity line or rubbing them in your body. There may be electricity or accidental power can occur and your animal may die.
  • Electricity is also a merciful master with an obedient slave. So please do not rush or mess with it. This can be fatal.
  • Do not build such a house below or near the electric line, which reduces the distance of the lines of the lines from the safe distance prescribed. Because this can cause unpleasant accidents at any time.
  • Disaster does not come by telling. Do not have your barn down or near the electricity line and do not make houses and cottages etc. This may cause fire in the barn / hut etc.
  • Do not bundle iron earrings with electric wires and ladders, electricity can come in and cause accidents.
  • Do not apply hand pump at the bottom or near the power line. Pipe etc. can touch the line and can cause accidents.
  • Do not put a bus, truck or trolley under or below the power line. Do not remove stuff from above. Lyle can contact the wire, sparking, flash over, etc., which can lead to a severe accident.
  • Do not remove long / high Tajia, chariot, pipes or sandalis from below the current line. It can touch the wire and cause accidents.
  • Do not try to get out of the line of dangling wire. You can touch the wire and it can cause an accident.
  • Do not use electricity by temporarily pulling wire / lanyard. It is unsafe and can cause an accident.
  • Give information to the nearest powerhouse / supplier as soon as possible to break the wire of electricity line, its hanging, break the cross-arrow of the girl and bend the pole.
  • If someone is holding the power, do not touch it directly, it can also cause you an accident. So separate such a person with a dry rope, a girl, a stick, or a cloth.
  • Turn off the electrical power of the fire immediately.
  • Do not put water on fire connected with electricity. It is dangerous to do this.
  • To extinguish the electric fire, use dry sand (fire) and electric fire extinguisher and report to the nearest fire station.
  • Do not work on live installation. Rather do the job after shutting down the installation.
  • Electricity work insulating platform like rubber mat, stand on a dry board of wood, etc., it protects you.
  • Please do not steal electricity. This is a social and legal crime. Such indecent acts can not be expected from a submissive citizen like you.
  • Do your work by using work safety devices such as glubs, rubber boots, safety belts, staircases, earthing devices, line devices, line testers, insulated plates and hand lines etc. on electric lines or appliances.
  • Power line and transference should not be done by unauthorized person but should be employed by the authorized person.
  • Do not think of injuring a mate. Immediately give him artificial self-esteem and make his first treatment and invite the doctor.
  • Do not drink anything to the unconscious. It can cause damage.
  • Examine wooden poles cross-arm from time to time Replace weak and rotten poles and cross-arms instantly, otherwise it can cause loss of life and property.
  • To resolve any difficulties related to electricity, contact the electrical safety nodalaya without any hesitation. We are always ready and committed to your support.

A Useful Things For The Consumer

Special attention is necessary on the following points by the consumer: -

  • Do the work related to electricity related to the state licenser electrical contractor.
  • Use only the ISI / approved goods / equipment in electrical installations. Poor goods and equipment are dangerous, unreliable and expensive.
  • Do not forget to keep electrical installation safe by the proper type of capable earthing and proper capacity of the fuse, without it can cause damage to your senses.
  • Put the switch in the foil wire only. Never attach the wire to the nuittal otherwise the accident can occur.
  • Do not perform electrical installations without obtaining license / permits / certificates. Ace is a legal crime and can be punished for it.
  • Do not work on live installation, but only after the power off of installation works.
  • Please do not steal electricity. This is a social and legal crime. It can not be expected from a reputable citizen like you.
  • In place of bulb, electronic choke tube light and CFL Use. This gives light more and electricity costs less.
  • Do your work by insulating platform such as rubber mat, dry platters, etc. It protects you from this.
  • Use electricity as per requirement. Do not waste it unnecessarily. It has the interest of both you and the nation.
  • Use the 3 pin plug instead of the 2 pin plug and the third meaning pin is essentially made, it is protected from it.
  • Do not load more than the test on the installation, it reduces its life and costs more electricity.
  • Do your work by using a work safety device such as glubs, rubber boots, safety belts, staircases, earthing devices, line testers, insulating plates and hand lines etc. on the power line or devices.
  • Do not bundle iron earrings with electric wire / lanyards etc., electricity can come and accident can occur.
  • Do not use electricity by temporarily pulling wire / lanyard. It is unsafe and can cause an accident.
  • Using the EarthLife Circuit Breaker (E.जे.सी.ਬੀ.) in electrical installation is necessary and beneficial from legal and security perspectives.
  • Instead of cut out in electrical installation, MCB Consumption is more convenient and safe.
  • Make sure to check your electrical installation from time to time, and make the shortcomings and errors mentioned as early as possible because it is safe and beneficial.
  • Regarding any problem relating to electricity, contact the electrical safety nodalaya without any hesitation. We are always ready to help you.
  • Save the power today for tomorrow's advanced future.
  • Use low capacity bulbs instead of more capacity bulbs.
  • Use Compact Florescent Lamp (CFL)
  • Close the equipment immediately after consumption.
  • Use the refrigerators at 3-4 degrees Celsius.
  • Play the washing machine on full load.
  • Consume the air conditioner at least (intelligently). In the consumption of an air conditioner, electricity is used as equal to 30 electric wings.
  • Keep lamps and light fixtures free from dirt.
  • Without the leakage of electrical wiring, the consumption of electricity without consuming the equipment is consumed, which is damaged.
  • To free the leakage of electrical wiring, get regular check-up by Megar from his licensed electric contractor and immediately change damaged wiring.
  • Do not work on live installation, but do the same by shutting down the installation light.
  • Energy conservation can also be done by reducing line losses.
  • The best quality of power equipment will also make the item in energy conservation.
  • Energy can be used to light / reduce the use of light bulb or toileblight.
  • Energy conservation can also be done by fixing the bad transformer line and other machines of the power suppliers at the right time or by adding new ones.
  • By using the methods of correct and safe use of electricity, it will also help to conserve energy by reaching the public regularly.
  • Uyogu can also be protected due to proper use / compliance of Indian electrical regulations.
  • In our country, the maintenance status / system of power lines, machines and transformers can not be corrected, it can also be conserve energy.
  • Conservation of energy can be done even if it is done at the right and right time by the technical staff responsible for the generation, transformer and distribution of energy.
  • Knowing the right and safe use of energy repeatedly, will help to conserve energy when given in a fun way.
  • Energy conservation can also be done by stopping electrical leakage / leakage of electricity.
  • I.S.I. Energy conservation can also be done by using certified electrical machines / wires and equipment.
  • Regarding saving electricity, contact the Department of Electrical Security (Directorate) / Authorized Institutions.
  • One unit power saving, 1.4 unit power generation is to increase.
  • Use electronic choke-containing tube in half to reduce the power consumption and get better light.
  • Save the electricity by installing all motorized stabilizers on the Mens supply in large commercial industrial installations.
  • Do not use motor for higher capacity than expected capacity, save electricity.
  • Switch the time in Street Light and save the power.
  • Today's era is an era of propaganda and dissemination, so in this case, any matter or message can be easily accessed to the public by using the effective means of propagation and dissemination and its positive results can be obtained.

Put Into Action

  • Electricity is also a merciful Master with an obedient slave, so be very careful and use it according to safety rules.
  • Do not touch the electric poles or stevair. There may be electricity in it or sudden electricity can come and you may get crashed.
  • Do not build such a house below or near the power line, so that between the lines of the line, the vertical / horizontal distance decreases according to the rules, otherwise it can cause an accident.
  • Do not apply hand pumps, tube wells near or below the power line. During the construction / repair, the Metallic can touch the pipeline wire and cause accidents.
  • Do not force the arganis to dry the cloth near the roof of the house, with electric poles / metallic rod and electric wires, electricity can come in and cause accidents.
  • Do not touch the strokes lying on the ground and hanging on the ground. In case of electricity, you can get crashed.
  • Do not forget to install electrical installations by fuse of fixed capacity.
  • Do not put the bus / truck / trolley etc. under or near the power line and do not take the luggage from above, otherwise touching the wire can be sparking, flash over and a terrible accident.
  • Do not remove high tajia, chariot, pipes or slabs from the bottom of the living overhead line, it can be contacted and accident can occur.

Precious Electric Safety In Negligible Value

  • Fire, electricity and water do not have any friends, so use electricity safely.
  • Do not obstruct your animals in electric poles and stays.
  • Do not wear the coil to dry the clothes near the electric wire.
  • Do not park the trolley just below the power line.
  • Do not build barns or trees near or below the power line and do not grow trees.
  • Do not use electricity by using katiya. Do not burn electricity from Earth wire / earthing.
  • I.S.I. Use of wiring material and tools.
  • Instant notice of electrical accident instantly to the Department of Electrical Security.
  • As per the rules of electrical installations / electrical equipment, the electrical safety department should be checked.
  • Do not tamper with electric wires.
  • In case of fire, turn off the power immediately.
  • Do not drink water on the fire.
  • Do not think of the accidental person as dead, take immediate care.
  • Electricity wiring / installation is done by state licensed electrical contractors.
  • Electrician may obtain wireman permit by taking examination conducted by the Department of Electrical Security.
  • Do the electricity work from Wireman Permit Stripe Mistry.
  • Put the switch in the foil wire only. Never put neutral.

Power Consumption By Equipment

The table below shows how much electricity you consume by using different tools. If there is no need to stop the equipment, save electricity for the country and reduce your electricity bill too.

Equipment and Capacity Size Wattage Monthly consumption of power unit If you run the devices then power Will be a unit consumed
One hour per day Six hours per day
Bulb 25 0.75 4.2 40 Hours
40 1.2 7.2 25 Hours
60 1.8 10.8 16 Hours 40 Minute
100 3 18 10 Hours
CFL 5 Watt 7 0.21 1.26 143 Hours
9 watt 11 0.33 1.98 90 Hours 55 Minute
11 watt 13 0.39 2.34 77 Hours
25 watt 27 0.81 4.86 37 Hours
Floretose Tube Copper with Choke 55 1.65 9.9 18 Hours 11 Minute
With electric choke 35 1.05 6.3 28 Hours 34 Minute
Lamp 15 0.45 2.7 66 Hours 40 Minute
Ceiling fan 36’’/48’’ 50 1.5 9 20 Hours
56’’ 60 1.8 10.8 16 Hours 40 Minute
60’’ 70 2.1 12.6 14 Hours 17 Minute
Table fan 12’’/16’’ 40 1.2 7.2 25 Hours
Electric press domestic 450/700 13.5 From 21 81 From 126 2 Hours 13 Minute From 1 Hour 25 Minute
Dhobi 1000 30 180 1 Hours
Tumble rod 1000 30 180 1 Hours
Geyser capacity 15-50 liters 2000 60 360 30 Minute
Instant 3000 90 540 20 Minute
A.C. 1 ton 1400 42 252 43 Minute
1.5 tons 1800 54 324 33 Minute
Air Cooler 170 5.1 30.6 5 Hours 53 Minute
Refrigerator small 225 2 units per day
Big 300 4 units per day
Toaster 800 24 144 1 Hours 15 Minute
Hot plate 1000/1500 30 From 45 180 From 270

1 Hours 40 Minute
Electric Kettle 1000/2000 30 From 60 180 From 360 1 Hours 30 Minute
Mixer Juicer Large 450 13.5 81 2 Hours 13 Minute
Washing machine automatic 325/1000 9.75 From 30 58.5 From 1800 3 Hours 45 Minute From 5 Hours
Semi Automatic 200 6 36 5 Hours
Vacuum cleaner 700-750 21 From 22.5 126 From 135 1 Hours 26 Minute From 1 Hours 20 Minute
Radios 15 0.45 2.7 66 Hours 40 Minute From 5 Hours
Tape recorders 15 0.6 3.6 50 Hours
T.V. 60 From 20 1.8 From 3.6 10.8 From 2.16 16 Hours 40 Minute From 8 Hours 20 Minute
Videos 40 1.2 7.2 25 Hours
Mosquito Repellant 5 0.15 0.9 200 Hours
Water purifiers 25 0.75 4.5 40 Hours
Computer 1100 From 150 3.45 18 From 27 10 Hours From 6 Hours 40 Minute

What To Do If There Is An Electrical Accident

  • Separate the accident with the help of a wooden or rubber stove.
  • Make available the first treatment, give the artificial swans immediately after the heart rate stops, massage it by mouth or on the chest to turn it on.
  • Call the doctor.
  • Report to the police.
  • Report to the Police Supplier.
  • Report to the concerned Office of Electrical Safety Directorate.
  • Post mortem of the dead as possible.

> Each electrical accident is examined by the Directorate of Electrical Safety, to prevent the accident, to convict the culprit, and to compensate for the damage done in this regard. So be careful and alert in this regard, so that you can not be deprived of the related benefits.It is legally mandatory and necessary to give information of each

> electrical accident to the Directorate of Electrical Safety. Please do not carelessly, inadvertently or otherwise may be in trouble and may be punished.

Some Necessary Guidelines For Building Houses Near The Power Line

Making a house near the electric line is not right and proper in terms of security. Legally arranged. That the horizontal and vertical distance of the drivers from the houses near the different voltage lines should not be less than the distance covered.

Each electrical accident is examined by the Directorate of Electrical Safety, to prevent the accident, to convict the culprit, and to compensate for the damage done in this regard. So be careful and alert in this regard, so that you can not be deprived of the related benefits.

It is legally mandatory and necessary to give information of each electrical accident to the Directorate of Electrical Safety. Please do not carelessly, inadvertently or otherwise may be in trouble and may be punished.

Height lectric line from the ground

Keeping in view the security, the minimum height of the power laden wire has been determined keeping in mind the voltage of the line, the location of the movement of the line and the means of movement there. The minimum height of wire from the ground should be as follows: -


S.No. Lane Voltage Line location Minimum height of wire from line wire
1 The following potential (up to 250 volts) and 'dark energy (up to 650 volts) line Road crossing 5.8 meters
2 High Impact Line (up to 33,000 volts) Yet 6.1 m
3 Low and low potential line Yet 5.5 m
4 High potential line Road up and down 5.8 meters
5 Low, medium and high potential (up to 11000 volts) line (1) If the wire is not insulated Yet 4.6 m
6 (2) If the wire is insulated Yet 4.0 meters
7 High potential (up to 33000 volts over 11,000 volts) line Yet 5.2 m

Extra high voltage (more than 33,000 volts) in the case of the line should not be less than its height of 5.2 meters to 0.3 m for every 33000 volts or part thereof which is more than 33000 volts. But crossing the road or on the road, this height should not be less than 6.1 meters. When making roads or making any other under the line, keep in mind that the minimum height from the line wire will not be reduced.

So, if you find that even if the height of the lining wire is below the fixed height, please inform it to the nearest power station / electricity supplier / electrical safety department so that it can be rectified and loss of life. Can be saved.

Electricity protection for persons / personnel living in tantage

  • No bulbs / tubes / fans should be used without use.
  • All switch off when leaving the tent.
  • Do not use water emission rod, electric heater or electric press without permission.
  • If any equipment such as water emission rad / electric heater is to be used in the use of electric press, then use the same for the socket outlet / plug point in the wiring of your tent using the electrical contractor.
  • No electrical items, cloth etc. should be kept on the wiring, nor should they be resorted to.
  • If there is no sparking in electrical jars or the insulation of the wiring melts, immediately switch off the main switch and give it to the control room immediately.
  • In order to avoid fire from accident and to avoid accident, apply SICO Mek Earth Leakage Protective Device approved electrical contractor approved by Electricity Department (Directorate) in his tent.
  • Fire, electricity and water do not have any friends, so do not harm yourself and children from electrical wires, bulb holders, tube fittings and plug pointer.
  • With the main switch in the wiring of your tent, make sure to cut the cutout and fuse of the appropriate capacity with the concerned electrical contractor.
  • Tin shade and metallic equipment are made by electric contractor.
  • First off the main switch when the fire starts from the fire and never fire the fire with water, but extinguish the fire from the dry sand / sand and inform it immediately to the control room.
  • Do not drink water to the person suffering from electric shock, but take it to nearby Regional Health Camp.
  • Do not get rid of the victim from the electric shock any time by hand or else you may also get electric shock. Remove such person from dry wires by dry sticks / dry wood.
  • Do not burn firewood / stove / gas burners near electrical wiring, otherwise it may get a fire from wiring short by heat.

Whom to get the work - done the electrical installation

The work of electrical installation is done by the state licensed contractor. Therefore, before undertaking electrical installation, you should ensure that the person you are working with has a valid license to work, otherwise the connection will not be available. It is a legal crime to get the job of a person without a license and to get work done without a licensed person, and for this, the workers who work and work can be punished.

License "A" "B" and "C" are provided and the work area varies according to the category of license.

For example, "A" category contractor can do all kind of electrical installation in the entire state. "B" category contractor is responsible for installation of low and medium plantation in the district in which the shop is located and from the district They can work in the transmitters. The contractor of "C" category can do the work of installation of low and medium scale up to 10 kilo feet in the district in which the shop is located.

Do not forget to get the electrical inspection done periodically

Regular arrangements for electrical installations have been arranged by the government. Example snap HT Installation and moderate potential

Inspection of periodical inspection of electrical installation at the interval of three years of installation and installation of low impact installation should be done by the Department of Electrical Safety. Therefore, please do inspection of your electrical installation at the prescribed intervals and the shortcomings / errors mentioned during the inspection will be done by the licensed contractor. It is very useful for safety and profit. So do not miss out on this system.

Electrical installation related to fair / exhibition etc.

It is necessary to follow the following provisions in relation to the related temporary installation of electricity, where there is a possibility that more than 250 watts of electricity should be used and more than 100 or more persons are likely to be formed at one time. : -

(1) To give notice to the concerned Assistant Electrical Inspector and the concerned District Magistrate of the Department of Electrical Security at least one week before using the installation.

(2) Receive from the electricity connection supplier.

(3) To get the electrical installation done by the state licensed electrical contractor.

(4) b. And L. Provide treasury challans related to the form and inspection fee to the concerned Assistant Electrical Inspector, Electricity Department, and make inspection. Obtain written permission from them for use in installation.

It is worth mentioning that it is a legal offense to use such a temporary electrical installment without obtaining permission from the Electricity Nidhiyalaya, and can be punished for it.

Do you wish to set up the generating set

If so, please do not forget to comply with the following provisions:

(1) Please inform the information about the generator installed from your District Magistrate.

(2) Get the electrical installation related to your generating set from the state licensed electrical contractor.

(3) 300 KVA B of the generating set of capacity And L. The treasury challan of the form and inspection fee related to the Assistant Electrical Inspector, and 300 KVA. B over the power generating set. And L. The treasury challan of the form and inspection fee should be made available to the electrical inspector and get the permission from them and get permission from them in written form to run the generator.

Do you want to take high-quality supplies

If yes, then please follow the following provisions:

(1) Electricity inspector, electrical safety, departments (Directorate) should be approved for approval related to electrical installation.

(2) According to the approved drawing, the work of electrical installation is done by the state licensed ("A" category) electrical contractor.

(3) b. And L. Receive the treasury challan of the form and inspection fee and make inspection by the Electricity Inspector and obtain permission in writing from them for use in installation.

It is worth mentioning that the use of high-powered installation without obtaining permission from the Electrical Security Directorate is a legal offense and can be punished for it.

Important Links

  • Home
  • Introduction
  • Organization
  • Application Form
  • Electricity Duty

Other Links

  • NOC for Commerical
  • NOC for Industrial (Nivesh Mitra)
  • Accident Intimation
  • Authorized Login Panel

Contact Details

  • Head Office:
    Vibhuti Block-2, Gomti Nagar, Lucknow - 226010
  • Phone no Telephone Number:
    0522-2720679, 2720716
  • Phone no Phone / Fax:
    0522 - 2720679
  • Email id Email:
    [email protected]
  • Terms & Conditions
  • Privacy Policy
  • Copyright Policy
  • Hyperlinking Policy
  • Help
  • Site Map
  • Screen Reader Access

Copyright © 2025 - All Rights Reserved, Directorate of Electrical Safety

Designed and Developed Through

feedbackfeedback Form

Visitor No.: Website Visitor

Last Updated Date : Saturday, 01, April 2025 | 11:30 AM